Comparison of complications associated with 8 shaped plates and cannulated screws use for the correction of angular deformities

Authors

  • Martha P. Valencia Chamorro Instituto de Ortopedia Infantil Roosevelt. Bogotá, Colombia
  • Luis F. Useche Instituto de Ortopedia Infantil Roosevelt. Bogotá, Colombia
  • Cristal Castellanos Mendoza Instituto de Ortopedia Infantil Roosevelt. Bogotá, Colombia
  • Fernando Cabrera Cardozo Pontificia Universidad Javeriana. Bogotá, Colombia
  • Jaime A. Dueñas Pontificia Universidad Javeriana. Bogotá, Colombia

DOI:

https://doi.org/10.1016/j.rccot.2016.02.003

Keywords:

idiopathic genu valgum, temporary hemiepiphysiodesis, percutaneous screws, eight-plate

Abstract

Background: The epiphysiodesis and hemiepiphysiodesis for correction of angular deformities in the lower limbs has evolved over time and today the use of transient techniques is preferred like are cannulated screws and eight plates. The aim of the study was to compare the outcome of patients with angular deformities treated with cannulated screws and eight shaped plates techniques and determine if there are differences in the outcome of patients.
Methods: A prospective cohort study was performed including pediatric patients treated at the Instituto de Ortopedia Infantil Roosevelt (IOIR) for angular deformities in their lower limbs from 2010 to 2012. A paired comparable cohort of patients in age, sex and diagnosis were assessed in their outcomes. For group 1 (eight shaped plate patient cohort) and group 2 (cannulated screws patient cohort) we evaluated the presence of pain, antalgic limp, edema, infection and inability to fully support lower limbs and crutches requirements.
Results: 6-month postoperative follow-up was performed. It was found in the assessments made in the first month of monitoring the presence of pain in 10 patients for group 1 and in 2 patients for group 2 (p < 0.05). We found that the antalgic limp, swelling, infection and inability to support have no statistically significant differences in the study group.
Discussion: The use of eight shaped plates is associated with the presence of increased pain in the immediate postoperative period in some patients, but this review suggests that a mediumterm pain improvement is seen in this group of patients, therefor not affecting the final clinical outcome.
Evidence level: III.

Downloads

Download data is not yet available.

Author Biographies

Martha P. Valencia Chamorro, Instituto de Ortopedia Infantil Roosevelt. Bogotá, Colombia

Departamento de Ortopedia Infantil, Instituto de Ortopedia Infantil Roosevelt, Bogotá, Colombia.

Luis F. Useche, Instituto de Ortopedia Infantil Roosevelt. Bogotá, Colombia

Departamento de Ortopedia y Traumatología, Instituto de Ortopedia Infantil Roosevelt, Bogotá, Colombia.

Cristal Castellanos Mendoza, Instituto de Ortopedia Infantil Roosevelt. Bogotá, Colombia

Epidemióloga clínica, Instituto de Ortopedia Infantil Roosevelt, Bogotá, Colombia.

Fernando Cabrera Cardozo, Pontificia Universidad Javeriana. Bogotá, Colombia

Residente de cuarto año de Ortopedia y Traumatología, Pontificia Universidad Javeriana, Bogotá, Colombia.

Jaime A. Dueñas, Pontificia Universidad Javeriana. Bogotá, Colombia

Residente de cuarto año de Ortopedia y Traumatología, Pontificia Universidad Javeriana, Bogotá, Colombia.

References

Phemister DB. Operative arrestment of longitudinal growth of bones in the treatment of deformities. J Bone Joint Surg Am. 1933;15:1-15.

Blount WP. Control of bone growth by epiphyseal stapling: a preliminary report. J Bone Joint Surg Am. 1949;31:464-78. https://doi.org/10.2106/00004623-194931030-00002

Raab P, Wild A, Seller K, Krauspe R. Correction of length discrepancies and angular deformities of the leg by Blount's epiphyseal stapling. Eur J Pediatr. 2001;160:668-74. https://doi.org/10.1007/s004310100834

Gorman TM, Vanderwerff R, Pond M, MacWilliams B, Santora S. Mechanical axis following staple epiphysiodesis for limb-length inequality. J Bone Joint Surg Am. 2009;91:2430-9. https://doi.org/10.2106/JBJS.H.00896

Bowen JR, Johnson WJ. Percutaneous epiphysiodesis. Clin Orthop. 1984;190:170-3. 6. Canale ST, Russell TA, Holcomb RL. Percutaneous epiphysiodesis: experimental study and preliminary clinical results. J Pediatr Orthop. 1986;6:150-6. https://doi.org/10.1097/01241398-198603000-00006

Metaizeau JP, Wong-Chung JM, Bertrand H, Pasquier P. Percutaneous epiphysiodesis using transphyseal screws (PETS). J Pediatr Orthop. 1998;18:363-9. https://doi.org/10.1097/01241398-199805000-00018

Nouh F, Kuo LA. Percutaneous epiphysiodesis using transphyseal screws (PETS). Prospective case study and review. J Pediatr Orthop. 2004;24:721-5. https://doi.org/10.1097/01241398-200411000-00023

Khoury JG, Tavares JO, McConnell S, Zeiders G, Sanders JO. Results of screw epiphysiodesis for the treatment of limb length discrepancy and angular deformity. J Pediatr Orthop. 2007;27:623-8. https://doi.org/10.1097/BPO.0b013e318093f4f4

Sánchez Mesa PA, Yamhure FH. Percutaneous hemiepiphysiodesis using transphyseal cannulated screws for genu valgum in adolescents. J Child Orthop. 2009;3:397-403. https://doi.org/10.1007/s11832-009-0203-8

Ilharreborde B, Gaumetou E, Souchet P, Fitoussi F, Presedo A, Pennec¸ot GF, et al. Efficacy and late complications of percutaneous epiphysiodesis with transphyseal screws. J Bone Joint Surg Br. 2012;94-B, 270-275. https://doi.org/10.1302/0301-620X.94B2.27470

Stevens PM. Guided growth for angular correction: a preliminary series using a tension band plate. J Pediatr Orthop. 2007;27:253-9. https://doi.org/10.1097/BPO.0b013e31803433a1

Ballal MS, Bruce CE, Nayagam S. Correcting genu varum and genu valgum in children by guided growth. Temporary hemiepiphysiodesis using tension band plates. J Bone Joint Surg [Br]. 2010;92-B:273-6. https://doi.org/10.1302/0301-620X.92B2.22937

Ghanema I, Karama JA, Widmann RF. Surgical epiphysiodesis indications and techniques: update. Curr Opin Pediatr. 2011;23:53-9. https://doi.org/10.1097/MOP.0b013e32834231b3

Burghardt RD, Herzenberg JE. Temporary hemiepiphysiodesis with the eight-plate for angular deformities: mid-term results. J Orthop Sci. 2010;15:699-704. https://doi.org/10.1007/s00776-010-1514-9

Published

2016-03-19

How to Cite

1.
Valencia Chamorro MP, Useche LF, Castellanos Mendoza C, Cabrera Cardozo F, Dueñas JA. Comparison of complications associated with 8 shaped plates and cannulated screws use for the correction of angular deformities. Rev. Colomb. Ortop. Traumatol. [Internet]. 2016 Mar. 19 [cited 2025 May 25];29(3):81-5. Available from: https://revistasccotorg.biteca.online/index.php/rccot/article/view/417

Issue

Section

Original research
QR Code
Crossref Cited-by logo
Article metrics
Abstract views
Galley vies
PDF Views
HTML views
Other views